Paper |
Title |
Page |
WEPA41 |
Maximizing Output of 3 MeV S-band Industrial Accelerator |
723 |
|
- D. Fischer, M. Denney, A.V. Mishin, S. Proskin, J. Roylance, L. Young
Varex Imaging, Salt Lake City, USA
|
|
|
Earlier, we have reported on a record-breaking 3-MeV Accelerator Beam Centerline (ABC) built in 2017-2018. An upgraded version of this 3-MeV S-band ABC has been developed at Varex Imaging as a key component for one of the most popular X-ray industrial linear accelerator systems, commonly used for security and NDT applications. Being significantly strained by excessive backstreaming, increasing of the ABC output is a challenging task. We describe these challenges and highlight high power test results. The triode gun and structure design improvements allowed us to raise stable output up to 530 Rad/min/1m at 3 MeV and up to 220 Rad/min/1m at 4.5 MeV with a widely available 2.5-MW/2.7-kW magnetron, while maintaining the spot size at 2 mm.
|
|
DOI • |
reference for this paper
※ doi:10.18429/JACoW-NAPAC2022-WEPA41
|
|
About • |
Received ※ 03 August 2022 — Revised ※ 08 August 2022 — Accepted ※ 11 August 2022 — Issue date ※ 20 September 2022 |
Cite • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|