  Mi­cro­phon­ics causes the cav­ity to de­tune. This study dis­cusses the mi­cro­phon­ics of 16 cry­omod­ules, 14 for LCLS-II and 2 for LCLS-II HE tested at CMTF. The peak de­tun­ing, as well as the RMS de­tun­ing for each cry­omod­ule, will be dis­cussed. For each cry­omod­ule, the data was taken with enough soak­ing time to pre­vent any ther­mal­iza­tion ef­fects which can show up in the de­tun­ing. Each data cap­ture taken was 30 min­utes or longer and sam­pled at 1 kHz.  
poster icon Poster MOPA24 [1.428 MB]  
DOI • reference for this paper ※ doi:10.18429/JACoW-NAPAC2022-MOPA24  
About • Received ※ 03 August 2022 — Revised ※ 10 August 2022 — Accepted ※ 11 August 2022 — Issue date ※ 20 September 2022