Paper | Title | Page |
---|---|---|
THXD3 |
Improved Multi-Dimensional Bunch Shape Monitor | |
|
||
Funding: This work was supported by the U.S. Department of Energy , Office of Basic Energy Sciences, under contract DE-SC0020590. RadiaBeam is developing the Bunch Shape Monitor (BSM) with improved performance that incorporates three major innovations. First, the collection efficiency is improved by adding a focusing field between the wire and the entrance slit. Second, an improvement of the measurement speed is achieved by sampling longitudinal profiles of multiple energy slices simultaneously. Finally, the design is augmented with both a movable wire and a microwave deflecting cavity to add functionality and enable measuring the transverse profile as a wire scanner. In this paper we present the design of the BSM and its sub-systems as well as the initial test results of the new focusing system at SNS beamline. |
||