TUPA11 Magnet System for a Compact Microtron Source electron, cavity, extraction, injection 363
 
  • S.A. Kahn, R.J. Abrams, M.A. Cummings, R.P. Johnson, G.M. Kazakevich
    Muons, Inc, Illinois, USA
 
  Funding: Work supported in part by U.S. D.O.E. SBIR grant DE-SC0013795.
A microtron can be an effective intense electron source. It can use less RF power than a linac to produce a similar energy because the beam will pass through the RF cavity several times. To produce a high-quality low-emittance beam with a microtron requires a magnetic system with a field uniformity $δ B/B<0.001. Field quality for a compact microtron with fewer turns is more difficult to achieve. In this study we describe the magnet for a compact S-band microtron that will achieve the necessary field requirements. The shaping of the magnet poles and shimming of the magnet iron at the outer extent of the poles will be employed to provide field uniformity. The extraction of the beam will be discussed.
 
DOI • reference for this paper ※ doi:10.18429/JACoW-NAPAC2022-TUPA11  
About • Received ※ 04 August 2022 — Revised ※ 14 August 2022 — Accepted ※ 06 September 2022 — Issue date ※ 08 October 2022