Paper | Title | Other Keywords | Page |
---|---|---|---|
MOPA59 | Prediction of Gaseous Breakdown for Plasma Cleaning of RF Cavities | simulation, cavity, plasma, electron | 174 |
|
|||
The quest for a high accelerating gradient in superconducting radio frequency cavity attracted scientists to adopt the plasma cleaning technology. Generating an efficient plasma inside a complex cavity structure for a desired frequency, gas types, and pressure for a given temperature is a challenge. The onset of discharge can be obtained from the well-known Paschen curve. Setting up an experiment is expensive and time-consuming, which may lead to a significant delay in the project. A high-fidelity computer simulation, modeling an arbitrary geometry and tracking the Paschen curve in a complex electromagnetic environment is therefore necessary. Ansys HFSS through its Finite Element Mesh (FEM) for the full-wave EM simulations combined with the electron impact ionization of gases enables the successful prediction of plasma breakdown for an arbitrary configuration for a wide frequency band and variety of gases. A comprehensive study will be demonstrated at the conference.
The author like to thank Robert Chao for the valuable discussions and his efforts in developing this capability in the Ansys Electronics Desktop. |
|||
DOI • | reference for this paper ※ doi:10.18429/JACoW-NAPAC2022-MOPA59 | ||
About • | Received ※ 01 August 2022 — Revised ※ 03 August 2022 — Accepted ※ 06 August 2022 — Issue date ※ 19 August 2022 | ||
Cite • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | ||
TUPA28 | Update on the Development of a Low-Cost Button BPM Signal Detector at AWA | pick-up, simulation, detector, electron | 409 |
|
|||
Funding: Work supported by the US Department of Energy, Office of Science. A single-pulse, high dynamic range, cost-effective BPM signal detector has been on the most wanted list of the Argonne Wakefield Accelerator (AWA) Test Facility for many years. The unique capabilities of the AWA beamline require BPM instrumentation with an unprecedented dynamic range, thus a cost-effective solution could be challenging to design and prototype. With the help of a better circuit model for a button BPM signal source, we are able to do the circuit simulations with more realistic input signals and make predictions much closer to realities. Our most recent design and prototype results are shared in this paper. |
|||
DOI • | reference for this paper ※ doi:10.18429/JACoW-NAPAC2022-TUPA28 | ||
About • | Received ※ 01 August 2022 — Revised ※ 08 August 2022 — Accepted ※ 11 August 2022 — Issue date ※ 09 October 2022 | ||
Cite • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | ||